Multifunctional 4DI 4DO RS485 Remote Control Switch Watchdog Relay Board Wired Remote IO Pulse Counter Module Modbus RTU N4CRB04

Multifunctional 4DI 4DO RS485 Remote Control Switch Watchdog Relay Board Wired Remote IO Pulse Counter Module Modbus RTU N4CRB04

12V Only Board
$14.55
Skip to product information
Multifunctional 4DI 4DO RS485 Remote Control Switch Watchdog Relay Board Wired Remote IO Pulse Counter Module Modbus RTU N4CRB04
Multifunctional 4DI 4DO RS485 Remote Control Switch Watchdog Relay Board Wired Remote IO Pulse Counter Module Modbus RTU N4CRB04
$14.55
Version

The N4CRB04 is a multi-functional RS485 I/O module developed and manufactured by eletechsup. In addition to supporting the standard MODBUS RTU protocol, it also has several features not found in older versions, such as a watchdog timer to ensure automatic reset in case of device malfunction, and an input port counting function to ensure no input signals are missed.




The N4CRB04 is a multifunctional product:

1. Compatible with NPN/PNP level inputs
2. Counts input pulses (Registers 0x0020-0x0023)
3. Multiple relay control modes: inching, self-locking, and interlocking
(registers 0x0000-0x0003)
4. Watchdog function (register 0x00F3)
5 Remote IO function (registers 0x00F5-0x00F6)
6 Automatic reporting of digital input(DI) status(register 0x00F8)
7 Input and output relationship(DI-DO relationship)(register 0x00FA)


Features:

1: Operating Voltage: DC 12V/24V
2: Operating Current: Standby current (all relays closed) 12MA, 1 relay open 40MA, 2 relays open 68MA, 3 relays open 93MA,4 relays open 120MA
3: 4ch 3-24V NPN/PNP Opto-Isolated Input Ports
4: The input-output relationship can be set to various association modes through instructions(Self-lockingdefault)/Interlocking/Momentary/Interlocking/Output=Input)
5: The input port can remotely control the output port of another board through the RS485 bus
6: The input port has a counting function. It can count pulses greater than 100MS (the pulse width can be set from 10 to 2000MS).
7: Support standard Modbus RTU command, function code, write 05/06/15/16 read 01/02/03
8: With hardware reset function, with TVS anti-surge protection
9: 4 opto-isolated inputs (NPN), 4 relay outputs (upgraded relays, more durable)
10: MODBUS commands can be made serial HyperTerminal (serial assistant) OR ''Modbus Poll''Enter;
11: Under the MODBUS command mode, it can support up to 254 devices in parallel
12: The default baud rate is 9600BPS. The baud rate can be selected by Conmand 2400 4800 9600 19200 38400 57600 115200BPS
13: The parity can be none parity, even parity and odd parity
14: The data sending and returning time can be set,with a maximum value of 1000ms
15: Size: 73 * 72 * 19mm(Only PCB Board);76 * 82*40mm(with Din Rail Box)
16: Weight: 80g(Only PCB Board);142g(with Din Rail Box)
17: Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC