{"product_id":"n4dac02-2ch-0-5v-0-10v-dac-module-rs485-modbus-rtu-voltage-signal-generator-with-1-accuracy-for-plc-measuring-instruments","title":"N4DAC02 2CH 0-5V\/0-10V DAC Module – RS485 Modbus RTU Voltage Signal Generator with 1% Accuracy for PLC Measuring Instruments","description":"\u003cp\u003e\u003cspan style=\"color: rgb(255, 0, 0); font-size: 22px;\"\u003eProduct Name: 2CH DC 12V 0-5V 0-10V Voltage Signal Generator DAC Converter Module RS485 Modbus RTU For PLC Measuring Instruments\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size:14pt;font-family:Verdana\"\u003ePackage inlcuded:\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-size:14pt;font-family:Verdana\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv\u003e\n  \u003cbr\u003e\n   1 PCS N4DAC02 12-25V 2 Channel PWM DAC RS485 Module\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845175897mvo_1787822635325.jpg?v=1789900389\" slate-data-type=\"image\" class=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\u003cspan style=\"font-size:18pt\"\u003eDescription: \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cdiv style=\"font-size:14pt\"\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n     1: Operating Voltage : DC 12 (DC 12-25V), recommended power supply with small ripple \n    \u003cbr\u003e\n    \u003cbr\u003e\n     2: Operating Current : 12-13MA \n    \u003cbr\u003e\n    \u003cbr\u003e\n     3: MODBUS RTU Command support 03 06 function code \n    \u003cbr\u003e\n    \u003cbr\u003e\n     4: CH1(O1) output voltage is 0-5V, maximum output current is 20MA. 1-5V accuracy 1%, \u0026lt;1V there is a ripple of 50HZ\/40MV. \n    \u003cbr\u003e\n    \u003cbr\u003e\n     CH2(O2) output voltage is 0-10V, maximum output current is 20MA. 2-10V accuracy 1%, \u0026lt;2V there is a ripple of 50HZ\/80MV. \n    \u003cbr\u003e\n    \u003cbr\u003e\n     5: The voltage resolution is 0.01V, the output accuracy is 1%; if the error is greater than 1%, it can be calibrated \n    \u003cbr\u003e\n    \u003cbr\u003e\n     6 :MODBUS commands can be made serial HyperTerminal (serial assistant) OR PLC Enter; \n    \u003cbr\u003e\n    \u003cbr\u003e\n     7 :Under the MODBUS command mode, it can support up to 247 devices in parallel \n    \u003cbr\u003e\n    \u003cbr\u003e\n     8 :Size: 45 * 35 * 15mm \n    \u003cbr\u003e\n    \u003cbr\u003e\n     9 :Weight: 10g\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:14pt\"\u003e\n  \u003cbr\u003e\u003cspan style=\"font-size:22px\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003eInstruction manual Please ask us after the purchase\u003c\/span\u003e\u003c\/span\u003e\n \u003c\/div\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cspan style=\"font-size:22px\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cdiv style=\"font-size:14pt\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eNote:\u003cbr\u003e\n   This is a low-cost digital-to-analog conversion module based on the PWM+ADC solution. It has the following disadvantages:\u003cbr\u003e\n   1 channel 1 (O1) has 1% accuracy at 1-5V, \u0026lt;1V has 50HZ\/40MV ripple, channel 2 (O2) has 1% accuracy at 2-10V, and \u0026lt;2V has 50HZ\/80MV Ripple.\u003cbr\u003e\n   2 channel 1 (O1) minimum output voltage is 0.05V, channel 2 (O2) minimum output voltage is 0.1V\u003cbr\u003e\n   3 There is a 10-20MS high pulse at the moment of power-on\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size:14pt\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\n  4-20MA\/0-20MA Sensor\n \u003cbr\u003e\n  Current and voltage signal transmission\n \u003cbr\u003e\n  Automated industry PLC\n \u003cbr\u003e\n  Smart Home,Home Automation ;\n \u003cbr\u003e\n  Identification system;\n \u003cbr\u003e\n  RS485 Remote monitoring;\n \u003cbr\u003e\n  Multimeter voltmeter\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\n \u003cbr\u003e\n  Interface introduction\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845176626uqp_1787822636008.jpg?v=1789900390\" slate-data-type=\"image\" class=\"clicked\"\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cbr\u003e\n  Wiring diagram \n \u003cbr\u003e\n \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845177338cri_1787822636687.jpg?v=1789900390\" slate-data-type=\"image\" class=\"clicked\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n \u003cp\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845178040gel_1787822637359.jpg?v=1789900391\" slate-data-type=\"image\" class=\"clicked\"\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845178689tos_1787822638006.jpg?v=1789900391\" slate-data-type=\"image\" class=\"clicked\"\u003e\u003c\/p\u003e\n \u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/1789845179376ihv_1787822638726.jpg?v=1789900391\" slate-data-type=\"image\" class=\"\"\u003e\u003c\/p\u003e\n \u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Eletechsup","offers":[{"title":"Default Title","offer_id":50422210101504,"sku":"N4DAC02","price":6.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/1700\/0192\/files\/Sa0dbbf97ffe44c88902dda98d789603eb_33772e8e-0c8d-463d-a9c4-03573ad52db1.webp?v=1789900386","url":"https:\/\/www.eletechsups.com\/products\/n4dac02-2ch-0-5v-0-10v-dac-module-rs485-modbus-rtu-voltage-signal-generator-with-1-accuracy-for-plc-measuring-instruments","provider":"eletechsup","version":"1.0","type":"link"}